Code | Code Description | Predetermined Area | Factory Settings | Unit |
P0 | Operating mode | C/H | C | - |
P1 | Hysteresis value | 0.1 - 30 | 2 | °C |
P2 | Temperature correction | -10.0 ~ 10.0 | 0 | °C |
P3 | Output delay | 0 - 10 | 0 | min |
P4 | High-Temperature Alarm | -50 ~ 110 | 110 | °C |
Press and hold the + button for 3 sec to restore the factory settings |
• C: cooling mode
• H: heating mode
E.g: P1 = 5
Cooling mode: when the detected temperature reaches the set value, the relay is disconnected and the temperature drops 5oC.
Heating mode: when the detected temperature reaches the set value, the relay is disconnected and the temperature rises 5oC.
This function ca be used to correct if there is a deviation between the detected temperature and the actual temperature.
AT = MT + CV ,where AT - actual value MT - measured temperature CV - correction value
If we measure the temperature to be 25.6oC and the actual is 25.8oC, CV can be set to 0.2 then the final temperature is 25.6 + 0.2 = 25.8
This function is used for compressor refrigeration. If you buy this thermostat for the fridge freezer, then this value must be set according to the pressure of compressor. The general setting is 3-6 minutes.
Set the high temperature alarm value. When the detected temperature exceeds, the screen will flash to alert you!
1. After powering the thermostat, you will se a red temperature which is the detected temperature and a green one which is controlling temperature
2. Press shortly the SET button and you will be able now to set the temperature using +/- buttons
3. Press and hold for 3 seconds the SET button and you will be able to set the thermostat parameters, according to the upper list, using the +/- buttons
4. Press shortly the SET button. Now, you can set the selected parameter.
5. Press and hold for 3 seconds the SET button or wait 5 seconds and the thermostat will be in the initial state.
This thermostat can measure and control...
49,99 lei
Molex Female to Molex Male + Serial ATA Power...
2,06 lei
This is a Single Row 6 Position Female Pin...
0,49 lei
This module has the advantage of being remote...
62,99 lei
Female Banana Plug for Panel (Black)
0,99 lei
Black Digital Thermometer with External Probe...
23,12 lei
Have you ever wanted to control the flow of a...
49,99 lei
Sinus Inverter DC-AC SPWM EGS002 EG8010 + IR2110
39,99 lei
This 3 A PWM driver module with reverse...
18,29 lei
Zener Diode 3.3 V 0.4W zener diode See...
0,49 lei